SYNOLOGY-UPS-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises
|
||
|
FROM SNMPv2-SMI
|
||
|
DisplayString, TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
Float
|
||
|
FROM NET-SNMP-TC
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF;
|
||
|
|
||
|
synoUPS MODULE-IDENTITY
|
||
|
LAST-UPDATED "201309110000Z"
|
||
|
ORGANIZATION "www.synology.com"
|
||
|
CONTACT-INFO
|
||
|
"Synology Inc.
|
||
|
Email: snmp@synology.com"
|
||
|
DESCRIPTION
|
||
|
"Characteristics of the ups information"
|
||
|
REVISION "201309110000Z"
|
||
|
DESCRIPTION
|
||
|
"Second draft."
|
||
|
::= { synology 4 }
|
||
|
|
||
|
synology OBJECT IDENTIFIER
|
||
|
::= { enterprises 6574 }
|
||
|
|
||
|
NonNegativeInteger ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This data type is a non-negative value."
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
|
||
|
--
|
||
|
-- The Device Identification group.
|
||
|
-- All objects in this group except for upsIdentName and
|
||
|
-- upsIdentAttachedDevices are set at device initialization
|
||
|
-- and remain static.
|
||
|
--
|
||
|
|
||
|
--
|
||
|
-- Device Group
|
||
|
--
|
||
|
|
||
|
upsDevice OBJECT IDENTIFIER ::= { synoUPS 1 }
|
||
|
|
||
|
upsDeviceModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device model"
|
||
|
::= { upsDevice 1 }
|
||
|
|
||
|
upsDeviceManufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device manufacturer"
|
||
|
::= { upsDevice 2 }
|
||
|
|
||
|
upsDeviceSerial OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device serial number."
|
||
|
::= { upsDevice 3 }
|
||
|
|
||
|
upsDeviceType OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device type (ups, pdu, scd, psu)"
|
||
|
::= { upsDevice 4 }
|
||
|
|
||
|
upsDeviceDescription OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device description."
|
||
|
::= { upsDevice 5 }
|
||
|
|
||
|
upsDeviceContact OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device administrator name."
|
||
|
::= { upsDevice 6 }
|
||
|
|
||
|
upsDeviceLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device physical location."
|
||
|
::= { upsDevice 7 }
|
||
|
|
||
|
upsDevicePart OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Device part number."
|
||
|
::= { upsDevice 8 }
|
||
|
|
||
|
upsDeviceMACAddr OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Physical network address of the device."
|
||
|
::= { upsDevice 9 }
|
||
|
|
||
|
--
|
||
|
-- UPS Group
|
||
|
--
|
||
|
|
||
|
upsInfo OBJECT IDENTIFIER ::= { synoUPS 2 }
|
||
|
|
||
|
upsInfoStatus OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS status."
|
||
|
::= { upsInfo 1 }
|
||
|
|
||
|
upsInfoAlarm OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS alarms"
|
||
|
::= { upsInfo 2 }
|
||
|
|
||
|
upsInfoTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Internal UPS clock time"
|
||
|
::= { upsInfo 3 }
|
||
|
|
||
|
upsInfoDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Internal UPS clock date"
|
||
|
::= { upsInfo 4 }
|
||
|
|
||
|
upsInfoModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS model"
|
||
|
::= { upsInfo 5 }
|
||
|
|
||
|
upsInfoMfr OBJECT IDENTIFIER ::= { upsInfo 6 }
|
||
|
|
||
|
upsInfoMfrName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS manufacturer"
|
||
|
::= { upsInfoMfr 1 }
|
||
|
|
||
|
upsInfoMfrDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS manufacturing date"
|
||
|
::= { upsInfoMfr 2 }
|
||
|
|
||
|
upsInfoSerial OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS serial number"
|
||
|
::= { upsInfo 7 }
|
||
|
|
||
|
upsInfoVendorID OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Vendor ID for USB devices"
|
||
|
::= { upsInfo 8 }
|
||
|
|
||
|
upsInfoProductID OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Product ID for USB devices"
|
||
|
::= { upsInfo 9 }
|
||
|
|
||
|
upsInfoFirmware OBJECT IDENTIFIER ::= { upsInfo 10 }
|
||
|
|
||
|
upsInfoFirmwareName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS firmware"
|
||
|
::= { upsInfoFirmware 1 }
|
||
|
|
||
|
upsInfoFirmwareAux OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Auxiliary device firmware"
|
||
|
::= { upsInfoFirmware 2 }
|
||
|
|
||
|
upsInfoTemperature OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degree C"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS temperature (degrees C)"
|
||
|
::= { upsInfo 11 }
|
||
|
|
||
|
upsInfoLoad OBJECT IDENTIFIER ::= { upsInfo 12 }
|
||
|
|
||
|
upsInfoLoadValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percentage"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Load on UPS (percent)"
|
||
|
::= { upsInfoLoad 1 }
|
||
|
|
||
|
upsInfoLoadHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percentage"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Load when UPS switches to overload condition (OVER) (percent)"
|
||
|
::= { upsInfoLoad 2 }
|
||
|
|
||
|
upsInfoID OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS system identifier"
|
||
|
::= { upsInfo 13 }
|
||
|
|
||
|
upsInfoDelay OBJECT IDENTIFIER ::= { upsInfo 14 }
|
||
|
|
||
|
upsInfoDelayStart OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Interval to wait before restarting the load (seconds)"
|
||
|
::= { upsInfoDelay 1 }
|
||
|
|
||
|
upsInfoDelayReboot OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Interval to wait before rebooting the UPS (seconds)"
|
||
|
::= { upsInfoDelay 2 }
|
||
|
|
||
|
upsInfoDelayShutdown OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Interval to wait after shutdown with delay command (seconds)"
|
||
|
::= { upsInfoDelay 3 }
|
||
|
|
||
|
upsInfoTimer OBJECT IDENTIFIER ::= { upsInfo 15 }
|
||
|
|
||
|
upsInfoTimerStart OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Time before the load will be started (seconds)"
|
||
|
::= { upsInfoTimer 1 }
|
||
|
|
||
|
upsInfoTimerReboot OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Time before the load will be rebooted (seconds)"
|
||
|
::= { upsInfoTimer 2 }
|
||
|
|
||
|
upsInfoTimerShutdown OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Time before the load will be shutdown (seconds)"
|
||
|
::= { upsInfoTimer 3 }
|
||
|
|
||
|
upsInfoTest OBJECT IDENTIFIER ::= { upsInfo 16 }
|
||
|
|
||
|
upsInfoTestInterval OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Interval between self tests"
|
||
|
::= { upsInfoTest 1 }
|
||
|
|
||
|
upsInfoTestResult OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Results of last self test"
|
||
|
::= { upsInfoTest 2 }
|
||
|
|
||
|
upsInfoDisplayLanguage OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Language to use on front panel"
|
||
|
::= { upsInfo 17 }
|
||
|
|
||
|
upsInfoContacts OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS external contact sensors"
|
||
|
::= { upsInfo 18 }
|
||
|
|
||
|
upsInfoEffciency OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Efficiency of the UPS (ratio of the output current on the input current) (percent)"
|
||
|
::= { upsInfo 19 }
|
||
|
|
||
|
upsInfoPower OBJECT IDENTIFIER ::= { upsInfo 20 }
|
||
|
|
||
|
upsInfoPowerValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt-Amps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Current value of apparent power (Volt-Amps)"
|
||
|
::= { upsInfoPower 1 }
|
||
|
|
||
|
upsInfoPowerNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt-Amps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal value of apparent power (Volt-Amps)"
|
||
|
::= { upsInfoPower 2 }
|
||
|
|
||
|
upsInfoRealPower OBJECT IDENTIFIER ::= { upsInfo 21 }
|
||
|
|
||
|
upsInfoRealPowerValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Watts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Current value of real power (Watts)"
|
||
|
::= { upsInfoRealPower 1 }
|
||
|
|
||
|
upsInfoRealPowerNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Watts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal value of real power (Watts)"
|
||
|
::= { upsInfoRealPower 2 }
|
||
|
|
||
|
upsInfoBeeperStatus OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS beeper status (enabled, disabled or muted)"
|
||
|
::= { upsInfo 22 }
|
||
|
|
||
|
upsInfoType OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS type"
|
||
|
::= { upsInfo 23 }
|
||
|
|
||
|
upsInfoWatchdogStatus OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS watchdog status (enabled or disabled)"
|
||
|
::= { upsInfo 24 }
|
||
|
|
||
|
upsInfoStart OBJECT IDENTIFIER ::= { upsInfo 25 }
|
||
|
|
||
|
upsInfoStartAuto OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS starts when mains is (re)applied"
|
||
|
::= { upsInfoStart 1 }
|
||
|
|
||
|
upsInfoStartBattery OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Allow to start UPS from battery"
|
||
|
::= { upsInfoStart 2 }
|
||
|
|
||
|
upsInfoStartReboot OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"UPS coldstarts from battery (enabled or disabled)"
|
||
|
::= { upsInfoStart 3 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- Battery Group
|
||
|
--
|
||
|
|
||
|
upsBattery OBJECT IDENTIFIER ::= { synoUPS 3 }
|
||
|
|
||
|
upsBatteryCharge OBJECT IDENTIFIER ::= { upsBattery 1 }
|
||
|
|
||
|
upsBatteryChargeValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery charge"
|
||
|
::= { upsBatteryCharge 1 }
|
||
|
|
||
|
upsBatteryChargeLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Remaining battery level when UPS switches to LB (percent)"
|
||
|
::= { upsBatteryCharge 2 }
|
||
|
|
||
|
upsBatteryChargeRestart OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum battery level for UPS restart after power-off"
|
||
|
::= { upsBatteryCharge 3 }
|
||
|
|
||
|
upsBatteryChargeWarning OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery level when UPS switches to Warning state (percent)"
|
||
|
::= { upsBatteryCharge 4 }
|
||
|
|
||
|
upsBatteryVoltage OBJECT IDENTIFIER ::= { upsBattery 2 }
|
||
|
|
||
|
upsBatteryVoltageValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt DC"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The magnitude of the present battery voltage."
|
||
|
::= { upsBatteryVoltage 1 }
|
||
|
|
||
|
upsBatteryVoltageNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt DC"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal battery voltage."
|
||
|
::= { upsBatteryVoltage 2 }
|
||
|
|
||
|
upsBatteryVoltageLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt DC"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum battery voltage, that triggers FSD status ."
|
||
|
::= { upsBatteryVoltage 3 }
|
||
|
|
||
|
upsBatteryVoltageHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volt DC"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Maximum battery voltage (Ie battery.charge = 100)."
|
||
|
::= { upsBatteryVoltage 4 }
|
||
|
|
||
|
upsBatteryCapacity OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "A"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery capacity (Ah)"
|
||
|
::= { upsBattery 3 }
|
||
|
|
||
|
upsBatteryCurrent OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Amp DC"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The present battery current."
|
||
|
::= { upsBattery 4 }
|
||
|
|
||
|
upsBatteryTemperature OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ambient temperature at or near the UPS Battery
|
||
|
casing."
|
||
|
::= { upsBattery 5 }
|
||
|
|
||
|
upsBatteryRuntime OBJECT IDENTIFIER ::= { upsBattery 6 }
|
||
|
|
||
|
upsBatteryRuntimeValue OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "Seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery runtime (seconds)"
|
||
|
::= { upsBatteryRuntime 1 }
|
||
|
|
||
|
upsBatteryRuntimeLow OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "Seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Remaining battery runtime when UPS switches to LB (seconds)"
|
||
|
::= { upsBatteryRuntime 2 }
|
||
|
|
||
|
upsBatteryRuntimeRestart OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
UNITS "Seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum battery runtime for UPS restart after power-off (seconds)"
|
||
|
::= { upsBatteryRuntime 3 }
|
||
|
|
||
|
upsBatteryAlarmThreshold OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery alarm threshold"
|
||
|
::= { upsBattery 7 }
|
||
|
|
||
|
upsBatteryDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery change date"
|
||
|
::= { upsBattery 8 }
|
||
|
|
||
|
upsBatteryMfrDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery manufacturing date"
|
||
|
::= { upsBattery 9 }
|
||
|
|
||
|
upsBatteryPacks OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of battery packs"
|
||
|
::= { upsBattery 10 }
|
||
|
|
||
|
upsBatteryPacksBad OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of bad battery packs"
|
||
|
::= { upsBattery 11 }
|
||
|
|
||
|
upsBatteryType OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery chemistry"
|
||
|
::= { upsBattery 12 }
|
||
|
|
||
|
upsBatteryProtection OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Prevent deep discharge of battery"
|
||
|
::= { upsBattery 13 }
|
||
|
|
||
|
upsBatteryEnergySave OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Switch off when running on battery and no/low load"
|
||
|
::= { upsBattery 14 }
|
||
|
|
||
|
--
|
||
|
-- Input Group
|
||
|
--
|
||
|
|
||
|
upsInput OBJECT IDENTIFIER ::= { synoUPS 4 }
|
||
|
|
||
|
upsInputVoltage OBJECT IDENTIFIER ::= { upsInput 1 }
|
||
|
|
||
|
upsInputVoltageValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input voltage"
|
||
|
::= { upsInputVoltage 1 }
|
||
|
|
||
|
upsInputVoltageMax OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Maximum incoming voltage seen"
|
||
|
::= { upsInputVoltage 2 }
|
||
|
|
||
|
upsInputVoltageMin OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum incoming voltage seen"
|
||
|
::= { upsInputVoltage 3 }
|
||
|
|
||
|
upsInputVoltageNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal input voltage"
|
||
|
::= { upsInputVoltage 4 }
|
||
|
|
||
|
upsInputVoltageExtend OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Extended input voltage range"
|
||
|
::= { upsInputVoltage 5 }
|
||
|
|
||
|
upsInputVoltageFault OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input voltage Fault"
|
||
|
::= { upsInputVoltage 6 }
|
||
|
|
||
|
|
||
|
upsInputTransfer OBJECT IDENTIFIER ::= { upsInput 2 }
|
||
|
|
||
|
upsInputTransferReason OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Reason for last transfer to battery"
|
||
|
::= { upsInputTransfer 1 }
|
||
|
|
||
|
upsInputTransferLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Low voltage transfer point"
|
||
|
::= { upsInputTransfer 2 }
|
||
|
|
||
|
upsInputTransferHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"High voltage transfer point"
|
||
|
::= { upsInputTransfer 3 }
|
||
|
|
||
|
upsInputTransferLowMin OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"smallest settable low voltage transfer point"
|
||
|
::= { upsInputTransfer 4 }
|
||
|
|
||
|
upsInputTransferLowMax OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"greatest settable low voltage transfer point"
|
||
|
::= { upsInputTransfer 5 }
|
||
|
|
||
|
upsInputTransferHighMin OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"smallest settable high voltage transfer point"
|
||
|
::= { upsInputTransfer 6 }
|
||
|
|
||
|
upsInputTransferHighMax OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"greatest settable high voltage transfer point"
|
||
|
::= { upsInputTransfer 7 }
|
||
|
|
||
|
upsInputTransferBoostLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Low voltage boosting transfer point"
|
||
|
::= { upsInputTransfer 8 }
|
||
|
|
||
|
upsInputTransferBoostHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"High voltage boosting transfer point"
|
||
|
::= { upsInputTransfer 9 }
|
||
|
|
||
|
upsInputTransferTrimLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Low voltage trimming transfer point"
|
||
|
::= { upsInputTransfer 10 }
|
||
|
|
||
|
upsInputTransferTrimHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"High voltage trimming transfer point"
|
||
|
::= { upsInputTransfer 11 }
|
||
|
|
||
|
upsInputSensitivity OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input power sensitivity"
|
||
|
::= { upsInput 3 }
|
||
|
|
||
|
upsInputQuality OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input power quality"
|
||
|
::= { upsInput 4 }
|
||
|
|
||
|
upsInputCurrent OBJECT IDENTIFIER ::= { upsInput 5 }
|
||
|
|
||
|
upsInputCurrentValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Amp"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input current (A)"
|
||
|
::= { upsInputCurrent 1 }
|
||
|
|
||
|
upsInputCurrentNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Amp"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal input current (A)"
|
||
|
::= { upsInputCurrent 2 }
|
||
|
|
||
|
upsInputFrequency OBJECT IDENTIFIER ::= { upsInput 6 }
|
||
|
|
||
|
upsInputFrequencyValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input line frequency (Hz)"
|
||
|
::= { upsInputFrequency 1 }
|
||
|
|
||
|
upsInputFrequencyNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal input line frequency (Hz)"
|
||
|
::= { upsInputFrequency 2 }
|
||
|
|
||
|
upsInputFrequencyLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input line frequency low (Hz)"
|
||
|
::= { upsInputFrequency 3 }
|
||
|
|
||
|
upsInputFrequencyHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Input line frequency high (Hz)"
|
||
|
::= { upsInputFrequency 4 }
|
||
|
|
||
|
upsInputFrequencyExtend OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Extended input frequency range"
|
||
|
::= { upsInputFrequency 5 }
|
||
|
|
||
|
--
|
||
|
-- The Output group.
|
||
|
--
|
||
|
|
||
|
upsOutput OBJECT IDENTIFIER ::= { synoUPS 5 }
|
||
|
|
||
|
upsOutputVoltage OBJECT IDENTIFIER ::= { upsOutput 1 }
|
||
|
|
||
|
upsOutputVoltageValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Output voltage (V)"
|
||
|
::= { upsOutputVoltage 1 }
|
||
|
|
||
|
upsOutputVoltageNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Volts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal output voltage (V)"
|
||
|
::= { upsOutputVoltage 2 }
|
||
|
|
||
|
upsOutputFrequency OBJECT IDENTIFIER ::= { upsOutput 2 }
|
||
|
|
||
|
upsOutputFrequencyValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Output frequency (Hz)"
|
||
|
::= { upsOutputFrequency 1 }
|
||
|
|
||
|
upsOutputFrequencyNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Hz"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal output frequency (Hz)"
|
||
|
::= { upsOutputFrequency 2 }
|
||
|
|
||
|
upsOutputCurrent OBJECT IDENTIFIER ::= { upsOutput 3 }
|
||
|
|
||
|
upsOutputCurrentValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Amp"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Output current (A)"
|
||
|
::= { upsOutputCurrent 1 }
|
||
|
|
||
|
upsOutputCurrentNominal OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "Amp"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Nominal output current (A)"
|
||
|
::= { upsOutputCurrent 2 }
|
||
|
|
||
|
--
|
||
|
-- The ambient group.
|
||
|
--
|
||
|
|
||
|
upsAmbient OBJECT IDENTIFIER ::= { synoUPS 6 }
|
||
|
|
||
|
upsAmbientTemperature OBJECT IDENTIFIER ::= { upsAmbient 1 }
|
||
|
|
||
|
upsAmbientTemperatureValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Ambient temperature (degrees C)"
|
||
|
::= { upsAmbientTemperature 1 }
|
||
|
|
||
|
upsAmbientTemperatureAlarm OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
UNITS "enabled/disabled"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Temperature alarm (enabled/disabled)"
|
||
|
::= { upsAmbientTemperature 2 }
|
||
|
|
||
|
upsAmbientTemperatureHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Temperature threshold high (degrees C)"
|
||
|
::= { upsAmbientTemperature 3 }
|
||
|
|
||
|
upsAmbientTemperatureLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Temperature threshold low (degrees C)"
|
||
|
::= { upsAmbientTemperature 4 }
|
||
|
|
||
|
upsAmbientTemperatureMax OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Maximum temperature seen (degrees C)"
|
||
|
::= { upsAmbientTemperature 5 }
|
||
|
|
||
|
upsAmbientTemperatureMin OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "degrees Centigrade"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum temperature seen (degrees C)"
|
||
|
::= { upsAmbientTemperature 6 }
|
||
|
|
||
|
upsAmbientHumidity OBJECT IDENTIFIER ::= { upsAmbient 2 }
|
||
|
|
||
|
upsAmbientHumidityValue OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Ambient relative humidity (percent)"
|
||
|
::= { upsAmbientHumidity 1 }
|
||
|
|
||
|
upsAmbientHumidityAlarm OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
UNITS "enabled/disabled"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Relative humidity alarm (enabled/disabled)"
|
||
|
::= { upsAmbientHumidity 2 }
|
||
|
|
||
|
upsAmbientHumidityHigh OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Relative humidity threshold high (percent)"
|
||
|
::= { upsAmbientHumidity 3 }
|
||
|
|
||
|
upsAmbientHumidityLow OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Relative humidity threshold low (percent)"
|
||
|
::= { upsAmbientHumidity 4 }
|
||
|
|
||
|
upsAmbientHumidityMax OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Maximum relative humidity seen (percent)"
|
||
|
::= { upsAmbientHumidity 5 }
|
||
|
|
||
|
upsAmbientHumidityMin OBJECT-TYPE
|
||
|
SYNTAX Float
|
||
|
UNITS "percent"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Minimum relative humidity seen (percent)"
|
||
|
::= { upsAmbientHumidity 6 }
|
||
|
|
||
|
--
|
||
|
-- The Driver group.
|
||
|
--
|
||
|
|
||
|
upsDriver OBJECT IDENTIFIER ::= { synoUPS 7 }
|
||
|
|
||
|
upsDriverName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Driver name"
|
||
|
::= { upsDriver 1 }
|
||
|
|
||
|
upsDriverVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Driver version (NUT release)"
|
||
|
::= { upsDriver 2 }
|
||
|
|
||
|
upsDriverVersionData OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Driver version data"
|
||
|
::= { upsDriver 3 }
|
||
|
|
||
|
|
||
|
upsDriverVersionInternal OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Internal driver version (if tracked separately)"
|
||
|
::= { upsDriver 4 }
|
||
|
|
||
|
upsDriverPollInterval OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "second"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Poll interval setup in configuration file"
|
||
|
::= { upsDriver 5 }
|
||
|
|
||
|
upsDriverPort OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Port setup in configuration file"
|
||
|
::= { upsDriver 6 }
|
||
|
|
||
|
upsDriverPollFrequency OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Poll frequency"
|
||
|
::= { upsDriver 7 }
|
||
|
|
||
|
upsDriverProductID OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Product ID"
|
||
|
::= { upsDriver 8 }
|
||
|
|
||
|
upsDriverSnmpVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Snmp version"
|
||
|
::= { upsDriver 9 }
|
||
|
|
||
|
--
|
||
|
-- The server group.
|
||
|
--
|
||
|
|
||
|
upsServer OBJECT IDENTIFIER ::= { synoUPS 8 }
|
||
|
|
||
|
upsServerInfo OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Server information"
|
||
|
::= { upsServer 1 }
|
||
|
|
||
|
upsServerVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Server version"
|
||
|
::= { upsServer 2 }
|
||
|
|
||
|
|
||
|
upsConformance OBJECT IDENTIFIER ::= { synoUPS 9 }
|
||
|
upsCompliances OBJECT IDENTIFIER ::= { upsConformance 1 }
|
||
|
upsGroups OBJECT IDENTIFIER ::= { upsConformance 2 }
|
||
|
|
||
|
upsCompliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for synoSystem entities which
|
||
|
implement the SYNOLOGY SYSTEM MIB."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { upsGroup }
|
||
|
|
||
|
::= { upsCompliances 1 }
|
||
|
|
||
|
upsGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
upsDeviceModel,
|
||
|
upsDeviceManufacturer,
|
||
|
upsDeviceSerial,
|
||
|
upsDeviceType,
|
||
|
upsDeviceDescription,
|
||
|
upsDeviceContact,
|
||
|
upsDeviceLocation,
|
||
|
upsDevicePart,
|
||
|
upsDeviceMACAddr,
|
||
|
upsInfoStatus,
|
||
|
upsInfoAlarm,
|
||
|
upsInfoTime,
|
||
|
upsInfoDate,
|
||
|
upsInfoModel,
|
||
|
upsInfoMfrName,
|
||
|
upsInfoMfrDate,
|
||
|
upsInfoSerial,
|
||
|
upsInfoVendorID,
|
||
|
upsInfoProductID,
|
||
|
upsInfoFirmwareName,
|
||
|
upsInfoFirmwareAux,
|
||
|
upsInfoTemperature,
|
||
|
upsInfoLoadValue,
|
||
|
upsInfoLoadHigh,
|
||
|
upsInfoID,
|
||
|
upsInfoDelayStart,
|
||
|
upsInfoDelayReboot,
|
||
|
upsInfoDelayShutdown,
|
||
|
upsInfoTimerStart,
|
||
|
upsInfoTimerReboot,
|
||
|
upsInfoTimerShutdown,
|
||
|
upsInfoTestInterval,
|
||
|
upsInfoTestResult,
|
||
|
upsInfoDisplayLanguage,
|
||
|
upsInfoContacts,
|
||
|
upsInfoEffciency,
|
||
|
upsInfoPowerValue,
|
||
|
upsInfoPowerNominal,
|
||
|
upsInfoRealPowerValue,
|
||
|
upsInfoRealPowerNominal,
|
||
|
upsInfoBeeperStatus,
|
||
|
upsInfoType,
|
||
|
upsInfoWatchdogStatus,
|
||
|
upsInfoStartAuto,
|
||
|
upsInfoStartBattery,
|
||
|
upsInfoStartReboot,
|
||
|
upsBatteryChargeValue,
|
||
|
upsBatteryChargeLow,
|
||
|
upsBatteryChargeRestart,
|
||
|
upsBatteryChargeWarning,
|
||
|
upsBatteryVoltageValue,
|
||
|
upsBatteryVoltageNominal,
|
||
|
upsBatteryVoltageLow,
|
||
|
upsBatteryVoltageHigh,
|
||
|
upsBatteryCapacity,
|
||
|
upsBatteryCurrent,
|
||
|
upsBatteryTemperature,
|
||
|
upsBatteryRuntimeValue,
|
||
|
upsBatteryRuntimeLow,
|
||
|
upsBatteryRuntimeRestart,
|
||
|
upsBatteryAlarmThreshold,
|
||
|
upsBatteryDate,
|
||
|
upsBatteryMfrDate,
|
||
|
upsBatteryPacks,
|
||
|
upsBatteryPacksBad,
|
||
|
upsBatteryType,
|
||
|
upsBatteryProtection,
|
||
|
upsBatteryEnergySave,
|
||
|
upsInputVoltageValue,
|
||
|
upsInputVoltageMax,
|
||
|
upsInputVoltageMin,
|
||
|
upsInputVoltageNominal,
|
||
|
upsInputVoltageExtend,
|
||
|
upsInputVoltageFault,
|
||
|
upsInputTransferReason,
|
||
|
upsInputTransferLow,
|
||
|
upsInputTransferHigh,
|
||
|
upsInputTransferLowMin,
|
||
|
upsInputTransferLowMax,
|
||
|
upsInputTransferHighMin,
|
||
|
upsInputTransferHighMax,
|
||
|
upsInputTransferBoostLow,
|
||
|
upsInputTransferBoostHigh,
|
||
|
upsInputTransferTrimLow,
|
||
|
upsInputTransferTrimHigh,
|
||
|
upsInputSensitivity,
|
||
|
upsInputQuality,
|
||
|
upsInputCurrentValue,
|
||
|
upsInputCurrentNominal,
|
||
|
upsInputFrequencyValue,
|
||
|
upsInputFrequencyNominal,
|
||
|
upsInputFrequencyLow,
|
||
|
upsInputFrequencyHigh,
|
||
|
upsInputFrequencyExtend,
|
||
|
upsOutputVoltageValue,
|
||
|
upsOutputVoltageNominal,
|
||
|
upsOutputFrequencyValue,
|
||
|
upsOutputFrequencyNominal,
|
||
|
upsOutputCurrentValue,
|
||
|
upsOutputCurrentNominal,
|
||
|
upsAmbientTemperatureValue,
|
||
|
upsAmbientTemperatureAlarm,
|
||
|
upsAmbientTemperatureHigh,
|
||
|
upsAmbientTemperatureLow,
|
||
|
upsAmbientTemperatureMax,
|
||
|
upsAmbientTemperatureMin,
|
||
|
upsAmbientHumidityValue,
|
||
|
upsAmbientHumidityAlarm,
|
||
|
upsAmbientHumidityHigh,
|
||
|
upsAmbientHumidityLow,
|
||
|
upsAmbientHumidityMax,
|
||
|
upsAmbientHumidityMin,
|
||
|
upsDriverName,
|
||
|
upsDriverVersion,
|
||
|
upsDriverVersionData,
|
||
|
upsDriverVersionInternal,
|
||
|
upsDriverPollInterval,
|
||
|
upsDriverPort,
|
||
|
upsDriverPollFrequency,
|
||
|
upsDriverProductID,
|
||
|
upsDriverSnmpVersion,
|
||
|
upsServerInfo,
|
||
|
upsServerVersion}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects providing basic information
|
||
|
of an synology ups entity."
|
||
|
::= { upsGroups 1 }
|
||
|
|
||
|
END
|