You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
378 lines
15 KiB
378 lines
15 KiB
<?xml version="1.0" encoding="UTF-8"?>
|
|
<zabbix_export>
|
|
<version>5.0</version>
|
|
<date>2021-06-19T10:42:56Z</date>
|
|
<groups>
|
|
<group>
|
|
<name>Modèles</name>
|
|
</group>
|
|
</groups>
|
|
<templates>
|
|
<template>
|
|
<template>Template_UPS_Eaton_SNMP</template>
|
|
<name>Template_UPS_Eaton_SNMP</name>
|
|
<templates>
|
|
<template>
|
|
<name>Template_SNMP_Device</name>
|
|
</template>
|
|
</templates>
|
|
<groups>
|
|
<group>
|
|
<name>Modèles</name>
|
|
</group>
|
|
</groups>
|
|
<applications>
|
|
<application>
|
|
<name>Batterie</name>
|
|
</application>
|
|
<application>
|
|
<name>Entrée</name>
|
|
</application>
|
|
<application>
|
|
<name>Informations carte</name>
|
|
</application>
|
|
<application>
|
|
<name>Informations onduleur</name>
|
|
</application>
|
|
<application>
|
|
<name>Sortie</name>
|
|
</application>
|
|
</applications>
|
|
<items>
|
|
<item>
|
|
<name>Emplacement onduleur</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.2.1.1.6.0</snmp_oid>
|
|
<key>emplacement.onduleur</key>
|
|
<delay>1h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>CHAR</value_type>
|
|
<inventory_link>LOCATION</inventory_link>
|
|
<applications>
|
|
<application>
|
|
<name>Informations onduleur</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Capacité batterie restante</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.2.4.0</snmp_oid>
|
|
<key>ups.battery.remaining</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>%</units>
|
|
<applications>
|
|
<application>
|
|
<name>Batterie</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
<triggers>
|
|
<trigger>
|
|
<expression>{last()}<10</expression>
|
|
<name>Charge batterie < 10%</name>
|
|
<priority>DISASTER</priority>
|
|
</trigger>
|
|
<trigger>
|
|
<expression>{last()}<20</expression>
|
|
<name>Charge batterie < 20%</name>
|
|
<priority>HIGH</priority>
|
|
<dependencies>
|
|
<dependency>
|
|
<name>Charge batterie < 10%</name>
|
|
<expression>{Template_UPS_Eaton_SNMP:ups.battery.remaining.last()}<10</expression>
|
|
</dependency>
|
|
</dependencies>
|
|
</trigger>
|
|
</triggers>
|
|
</item>
|
|
<item>
|
|
<name>Fréquence en entrée</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.3.1.0</snmp_oid>
|
|
<key>ups.freq.in</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>Hz</units>
|
|
<applications>
|
|
<application>
|
|
<name>Entrée</name>
|
|
</application>
|
|
</applications>
|
|
<preprocessing>
|
|
<step>
|
|
<type>MULTIPLIER</type>
|
|
<params>0.1</params>
|
|
</step>
|
|
</preprocessing>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Fréquence en sortie</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.4.2.0</snmp_oid>
|
|
<key>ups.freq.out</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>Hz</units>
|
|
<applications>
|
|
<application>
|
|
<name>Sortie</name>
|
|
</application>
|
|
</applications>
|
|
<preprocessing>
|
|
<step>
|
|
<type>MULTIPLIER</type>
|
|
<params>0.1</params>
|
|
</step>
|
|
</preprocessing>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Version firmware</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.1.3.0</snmp_oid>
|
|
<key>ups.fw.version</key>
|
|
<delay>1h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>TEXT</value_type>
|
|
<inventory_link>SOFTWARE</inventory_link>
|
|
<applications>
|
|
<application>
|
|
<name>Informations onduleur</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Charge de l'onduleur</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.4.1.0</snmp_oid>
|
|
<key>ups.load</key>
|
|
<delay>2m</delay>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>%</units>
|
|
<applications>
|
|
<application>
|
|
<name>Sortie</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
<triggers>
|
|
<trigger>
|
|
<expression>{last()}>80</expression>
|
|
<name>L'onduleur est en surcharge</name>
|
|
<priority>AVERAGE</priority>
|
|
</trigger>
|
|
</triggers>
|
|
</item>
|
|
<item>
|
|
<name>Modèle</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.1.2.0</snmp_oid>
|
|
<key>ups.model</key>
|
|
<delay>2h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>TEXT</value_type>
|
|
<inventory_link>MODEL</inventory_link>
|
|
<applications>
|
|
<application>
|
|
<name>Informations onduleur</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Adresse IP</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.705.1.12.1.0</snmp_oid>
|
|
<key>ups.nic.ip</key>
|
|
<delay>2h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>CHAR</value_type>
|
|
<inventory_link>OOB_IP</inventory_link>
|
|
<applications>
|
|
<application>
|
|
<name>Informations carte</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Adresse MAC</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.2.1.2.2.1.6.2</snmp_oid>
|
|
<key>ups.nic.mac</key>
|
|
<delay>2h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>CHAR</value_type>
|
|
<inventory_link>MACADDRESS_A</inventory_link>
|
|
<applications>
|
|
<application>
|
|
<name>Informations carte</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Numéro série</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.705.1.1.7.0</snmp_oid>
|
|
<key>ups.serial</key>
|
|
<delay>1h</delay>
|
|
<history>180d</history>
|
|
<trends>0</trends>
|
|
<value_type>TEXT</value_type>
|
|
<applications>
|
|
<application>
|
|
<name>Informations onduleur</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>État de l'onduleur</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.2.5.0</snmp_oid>
|
|
<key>ups.status</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<applications>
|
|
<application>
|
|
<name>Entrée</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
<triggers>
|
|
<trigger>
|
|
<expression>{last()}=2</expression>
|
|
<name>L'onduleur est sur batterie</name>
|
|
<priority>DISASTER</priority>
|
|
</trigger>
|
|
</triggers>
|
|
</item>
|
|
<item>
|
|
<name>Autonomie restante</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.2.1.0</snmp_oid>
|
|
<key>ups.time.remaining</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>s</units>
|
|
<applications>
|
|
<application>
|
|
<name>Batterie</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Voltage en entrée</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.534.1.3.4.1.2.1</snmp_oid>
|
|
<key>ups.voltage.in</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>V</units>
|
|
<applications>
|
|
<application>
|
|
<name>Entrée</name>
|
|
</application>
|
|
</applications>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
<item>
|
|
<name>Voltage en sortie</name>
|
|
<type>SNMP_AGENT</type>
|
|
<snmp_oid>.1.3.6.1.4.1.705.1.7.2.1.2.1</snmp_oid>
|
|
<key>ups.voltage.out</key>
|
|
<history>180d</history>
|
|
<trends>1825d</trends>
|
|
<units>V</units>
|
|
<applications>
|
|
<application>
|
|
<name>Sortie</name>
|
|
</application>
|
|
</applications>
|
|
<preprocessing>
|
|
<step>
|
|
<type>MULTIPLIER</type>
|
|
<params>0.1</params>
|
|
</step>
|
|
</preprocessing>
|
|
<request_method>POST</request_method>
|
|
</item>
|
|
</items>
|
|
</template>
|
|
</templates>
|
|
<graphs>
|
|
<graph>
|
|
<name>Alimentation</name>
|
|
<graph_items>
|
|
<graph_item>
|
|
<drawtype>BOLD_LINE</drawtype>
|
|
<color>C80000</color>
|
|
<item>
|
|
<host>Template_UPS_Eaton_SNMP</host>
|
|
<key>ups.freq.in</key>
|
|
</item>
|
|
</graph_item>
|
|
<graph_item>
|
|
<sortorder>1</sortorder>
|
|
<drawtype>GRADIENT_LINE</drawtype>
|
|
<color>00C800</color>
|
|
<yaxisside>RIGHT</yaxisside>
|
|
<item>
|
|
<host>Template_UPS_Eaton_SNMP</host>
|
|
<key>ups.voltage.in</key>
|
|
</item>
|
|
</graph_item>
|
|
</graph_items>
|
|
</graph>
|
|
<graph>
|
|
<name>Capacité batterie</name>
|
|
<ymin_type_1>FIXED</ymin_type_1>
|
|
<ymax_type_1>FIXED</ymax_type_1>
|
|
<graph_items>
|
|
<graph_item>
|
|
<color>00C800</color>
|
|
<item>
|
|
<host>Template_UPS_Eaton_SNMP</host>
|
|
<key>ups.battery.remaining</key>
|
|
</item>
|
|
</graph_item>
|
|
</graph_items>
|
|
</graph>
|
|
<graph>
|
|
<name>Sortie</name>
|
|
<graph_items>
|
|
<graph_item>
|
|
<drawtype>BOLD_LINE</drawtype>
|
|
<color>C80000</color>
|
|
<item>
|
|
<host>Template_UPS_Eaton_SNMP</host>
|
|
<key>ups.freq.out</key>
|
|
</item>
|
|
</graph_item>
|
|
<graph_item>
|
|
<sortorder>1</sortorder>
|
|
<drawtype>GRADIENT_LINE</drawtype>
|
|
<color>00C800</color>
|
|
<yaxisside>RIGHT</yaxisside>
|
|
<item>
|
|
<host>Template_UPS_Eaton_SNMP</host>
|
|
<key>ups.voltage.out</key>
|
|
</item>
|
|
</graph_item>
|
|
</graph_items>
|
|
</graph>
|
|
</graphs>
|
|
</zabbix_export>
|
|
|